The Vertiv PowerIT Switched Outlet Level Monitored High Density Rack Power Distribution Unit (rPDU) VP7U62A0 is an upgradeable, 60/63A, 240V, 2U, horizontal rPDU with input monitoring and outlet level monitoring and switching. It has 24 Combination C13/C19 outlets that provide the flexibility to connect C14 and C20 plugs in the same outlet interchangeably. This unit also has a 1P+N+E (IP44) plug providing 14.4kW of power capacity. This model allows you to turn off outlets to avoid accidental overloads and remotely power cycle equipment to reboot unresponsive critical IT equipment. The hot-swappable Interchangeable Monitoring Device (IMD-5M) has ports for serial communication and environmental monitoring, while the dual gigabit ethernet ports simplify the management of multiple PDUs with fault-tolerant daisy chaining or IP aggregation capabilities. Plus, it includes a three-year warranty that is extendable to five years if registered within 120 days of purchase.
Upgradeable Switched Outlet Level Monitored rPDUs provide reliable power distribution to critical IT equipment while delivering individual outlet level control and a comprehensive view of outlet level power usage via remote network access. Includes environmental monitoring capabilities to obtain real-time environmental metrics. With the Geist Upgradeable hot-swap technology, users may easily update the rPDU technology with the addition of the appropriate Interchangeable Monitoring Device (IMD) as business needs change.
The Vertiv PowerIT Monitored Outlet Level High Density Rack Power Distribution Unit (rPDU) VP6U62A0 is an upgradeable, 60/63A, 240V, 2U, horizontal rPDU with input and outlet level monitoring. It has 24 Combination C13/C19 outlets that provide the flexibility to connect C14 and C20 plugs in the same outlet interchangeably. It also has a 1P+N+E (IP44) plug with 14.4kW of power capacity. The hot-swappable Interchangeable Monitoring Device (IMD-5M) has ports for serial communication and environmental monitoring, while the dual gigabit ethernet ports simplify the management of multiple PDUs with fault-tolerant daisy chaining or IP aggregation capabilities. This model is UL/CE dual listed, meeting an important requirement for data centers. It is also RoHS-certified and individually tested to ensure your network is powered by a reliable power distribution unit. Plus, it includes a three-year warranty that is extendable to five years if registered within 120 days of purchase.
Rack Transfer Switch (RTS) delivers redundant power to single corded devices. The RTS automatically detects the loss of power and switches the power load (no phase-syncronization required) to the alternative power source in less than 4-8 milliseconds without the need for human intervention.
Rack Transfer Switch (RTS) delivers redundant power to single corded devices. The RTS automatically detects the loss of power and switches the power load (no phase-syncronization required) to the alternative power source in less than 4-8 milliseconds without the need for human intervention.
The Vertiv PowerIT Switched Unit Level Monitored High Density Rack Power Distribution Unit (rPDU) VP5U62A0 is an upgradeable, 60/63A, 240V, 2U, horizontal rPDU with input monitoring and outlet level switching. It has 24 Combination C13/C19 outlets that provide the flexibility to connect C14 and C20 plugs in the same outlet interchangeably. This unit also has a 1P+N+E (IP44) plug providing 14.4kW of power capacity. This model allows you to turn off outlets to avoid accidental overloads and remotely power cycle equipment to reboot unresponsive critical IT equipment. The hot-swappable Interchangeable Monitoring Device (IMD-5M) has ports for serial communication and environmental monitoring, while the dual gigabit ethernet ports simplify the management of multiple PDUs with fault-tolerant daisy chaining or IP aggregation capabilities. Plus, it includes a three-year warranty that is extendable to five years if registered within 120 days of purchase.
Rack Transfer Switch (RTS) delivers redundant power to single corded devices. The RTS automatically detects the loss of power and switches the power load (no phase-syncronization required) to the alternative power source in less than 4-8 milliseconds without the need for human intervention.
Rack Transfer Switch (RTS) delivers redundant power to single corded devices. The RTS automatically detects the loss of power and switches the power load (no phase-syncronization required) to the alternative power source in less than 4-8 milliseconds without the need for human intervention.