APC GVSUPS60KGS is a robust 60kVA / 60kW online double-conversion Uninterruptible Power Supply (UPS) designed to provide continuous, high-quality power for mission-critical applications. It ensures zero transfer time and complete protection against power outages, voltage fluctuations, surges, and electrical noise.
Vertiv Liebert APS AS3. Output power capacity: 15 kVA, Output power: 13500 W, Input operation voltage (min): 200 V. Battery voltage: 1.67 V, Typical backup time at full load: 300 min. Form factor: Rackmount/Tower, Product color: Black, Cooling type: Active. Width: 17.3" (440 mm), Depth: 31.5" (800 mm), Height: 41.7" (1060 mm)
Vertiv Liebert APS AS4. Output power capacity: 20 kVA, Output power: 18000 W, Input operation voltage (min): 200 V. Battery voltage: 1.67 V, Typical backup time at full load: 300 min. Product color: Black, Cooling type: Active, Safety: IEC/EN/AS 62040-1:2008, UL 1778 4th Ed & CSA 22.2 No. 107.1. Width: 17.3" (440 mm), Depth: 33.5" (850 mm), Height: 48.8" (1240 mm)
Vertiv Liebert APS AS5. Output power capacity: 10 kVA, Output power: 9000 W, Input operation voltage (min): 200 V. Battery voltage: 1.67 V, Typical backup time at full load: 300 min. Product color: Black, Cooling type: Active, Safety: UL 1778 4th Ed and CSA 22.2 No. 107.1. Width: 17.3" (440 mm), Depth: 31.5" (800 mm), Height: 27.4" (695 mm)
Eaton 93PX8K 7.5kW UPS bundle/kit model that includes a 7.5kW Power Module, 8k-MBP, one EBM and NETWORK-M3 card. 9U Rack-mountable - 5.40 Hour Recharge - 230 V AC, 120 V AC Input - 208 V AC, 120 V AC Output - Three Phase - Pure Sine Wave - Serial Port - USB - LCD Display - 2 x NEMA L21-30R Receptacle(s) - Network-M3 Card, INDGW-M3 Card, RS-232 - TAA Compliant
High performance, redundant power protection with scalable power and runtime for space-constrained server rooms, and voice and data networks.
DCPM28HN54SH0 Features- Rack Mount1U rackmountable. Hardware included.- Paralleling CapabilityIncrease capacity, run time or redundancy by adding further units in parallel- Hot-swap rectifiersCost of ownership is reduced by the use of light weight, modular, true hot-swappable rectifiers which facilitate easy maintenance- Wide temperature rangeEquipment capable of operating in an extended temperature environment suits a wider range of applications and can reduce or remove the need for HVAC.- Serial ConnectivityUse any Home Automation network to monitor and control the S20 through its RS-232 serial port. For information on how to communicate with the S20, see APC's Application Note #102. Crestron and AMX installers should visit their respective websites for information on how to integrate the S20 into those networks.- Serial ConnectivityProvides management of the UPS via a serial port.- Input power factor correctionMinimizes installation costs by enabling the use of smaller generators and cabling.- Hot Expansion Capability- Modular Rectifiers- N+1 RedundancyMagnum XS Rectifier Features & BenefitsAvailability- N+1 RedundancySystem integrity is maintained even in the event of a rectifier failure ensuring maximum uptime and system availability- Paralleling CapabilityIncrease capacity, run time or redundancy by adding further units in parallel- Wide temperature rangeEquipment capable of operating in an extended temperature environment suits a wider range of applications and can reduce or remove the need for HVAC.Adaptability- Hot Expansion CapabilityProtects your investment in DC power by enabling expansion or configuration simply by adding additional rectifiers- Paralleling CapabilityIncrease capacity, run time or redundancy by adding further units in parallel- Input power factor correctionReduced utility and wiring costs. Increasingly a legislative or specification requirement.Manageability- Integrated Control CircuitryMonitoring and reporting of vital rectifier functions, control of output current and voltage.Serviceability- Hot-swap rectifiersCost of ownership is reduced by the use of light weight, modular, true hot-swappable rectifiers which facilitate easy maintenanceConvenience- Input power factor correctionReduced utility and wiring costs. Increasingly a legislative or specification requirement.
GXT5-6000 UPS with pre-installed GXT3/GXT4 PODs, 4900VA/4600W L6-30 plug. This is the direct replacement for the GXT4-6000RTL630.
The ATEN Professional Online UPS is an exceptional and innovative electrical apparatus that provides emergency power to a load when the input power source, or the main one, fails. The basic technology of an online UPS is the same as in a standby or line-interactive UPS, however, the ATEN Professional Online UPS provides a much greater current of AC-to-DC battery-charger / rectifier where the rectifier and inverter are designed to run continuously with improved cooling systems.In all our years of working with computers, we’ve found the vast majority of hardware failures can be directly attributed to the stress hardware components experience during the shut-down and startup process, especially if power surges or blackouts are involved. With severe weather, the aging electrical grid, and hazards lurk inside users' own walls, their equipment is under constant attack from power problems. Even a brief loss of power, sags, or a momentary surge can ruin users' equipment and destroy irreplaceable data. Desktop computers don’t have batteries built-in like laptops do. If users are working on a desktop during a power outage, the system would come to an immediate halt. Not only would users lose their work, but the process imposes unnecessary stress on their machine.If a UPS is present and a power loss occurs, the batteries in the UPS would keep the power steady and unchanged. The ATEN Professional Online UPS adjusts incoming AC power, provides battery backup to pass through most outages, and saves open files automatically. When power is restored, the UPS begins recharging its batteries. The Online UPS unit continuously filters wall power through the battery system. Since the attached electronics run completely off the battery (that are always topped off by the external power supply), there is never a single millisecond of power interruption when there is power loss or voltage regulation issues. The Online UPS unit thus acts as an electronic firewall between users' devices and the outside world by stabilizing all the electricity to which users' devices are exposed. The UPS has one USB port and one serial port that allow connection and communication between the UPS and the connected computer. Power management software installed on the connected computer(s) gives IT professionals the tools they need to easily monitor and manage their backup power. This advanced software allows users to access vital UPS battery conditions, load levels, and runtime information as well as provide unattended shut down of network computers and virtual machines connected to a battery backup during a power event. The ATEN Professional Online UPS offers a different way to access detailed UPS settings and information with an LCD screen. The illuminated LCD screen displays input voltage, battery capacity, and more, and includes a three-button configuration interface and audible alarms for different modes of operation. Note: When any battery pack, provided or purchased separately, is not in use, please recharge it for 4 ~ 6 hours every 3 ~ 6 months.
Note: Search results and information may differ as they are provided by a third party.
In Stock*: Product stock is updated from the last business day and can change.
MFR: Netgear, Inc
Qty: 1
Part #: GS105NA
