Active response controlsMonitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.Total Cost of OwnershipEconomizationAchieved by utilizing cool ambient air during winter months to take advantage of economizer hours and eliminating compressor operation.Indirect Heat ExchangeA polymer heat exchanger allows the data center and outside airstreams to remain separated, thereby preventing contamination and humidity influences to the data center airstream.Zero White SpaceAll cooling equipment is placed outside the data center, allowing for valuable white space to be fully utilized for IT equipment.Variable speed fansVariable speed fans reduce energy consumption during off-peak cooling periods.Supplemental Mechanical CoolingProvides extra capacity to augment economization, extending annual hours of energy savings.AvailabilityActive response controlsMonitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.Redundant ComponentsSingle points of failure in the system have redundant compononents to maintain availability and reliability.EconomyGreen RefrigerantEnvironmentally friendly refrigerant that can offer LEED points.Pulse Powered Water Treatment SystemEliminates the use of chemicals in the system, allowing the water to be re-used or drained without harming the environment.AgilityPre-engineered systemAllows for fast design and installationScalable DesignModular design provides scalable solutions to add cooling as demand increases.ServiceabilityOperational ServiceAllows critical components to be maintained/replaced while the system is in operation.Easy service accessAllows for all serviceable components to be replaced/maintained by easily accessible panels/doors.
Uniflair Plenum Chamber - Frame Size 3 - Gray
NetShelter SX 48U 750mm Wide x 1200mm Deep Enclosure Without Sides Without Doors Black
Air distribution for power dense racks and low pressure areas.Works with rack fan panel to turn the unit on or off based on temperature.
Mounting bracket for mounting a NetBotz Camera Pod inside a data center rack or network closet Not compatible with NetBotz 200, 300, 400, 500 or 700 series appliances Designed only for use with select Camera pods
Battery failure notificationProvides early-warning fault analysis on batteries enabling timely preventive maintenanceModular designIncreases adaptability with an open architecture configurable to any IT environment.Modular designModular construction - can be deployed as a non-standby and migrate to a standby (UPS) system.Hot-swappable batteriesEnsures clean, uninterrupted power to protected equipment while batteries are being replacedBattery modules connected in parallelDelivers higher availability through redundant batteries.Modular designProvides fast serviceability and reduced maintenance requirements via self-diagnosing, field-replaceable modules.Locking cabinetPrevents unauthorized access to the UPS.Modular designModular design provides scalable solutions to add cooling as demand increases.Battery replacement without toolsAllows quick, easy battery replacement.Front-access servicingSimplifies installation and maintenance while minimizing space requirements
AvailabilityPredictable coolingPlacing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.Rack Inlet Temperature ControlReduces the risk of hot spots at the rack levelActive response controlsMonitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.Total Cost of OwnershipVariable speed fansVariable speed fans reduce energy consumption during off-peak cooling periods.In-Row architectureCaptures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.
Introducing the redesigned APC NetShelter SX rack enclosure - trusted, versatile, and built for demanding IT environments. With larger load capacities and more space for equipment, it enables higher-density computing. Choose from standard, wide, extra wide, and large-depth options. The modern look is perfect for colocation and customer-facing businesses. Simplify workflows with easy access to cabling and equipment, and optimize airflow and cable management with our wide range of APC accessories. The 270° (180° bayed) opening doors keep aisles clear, while 80% door perforation improves airflow for high-powered servers. Built sustainably with all-steel construction, it lasts for years and can be used for various applications. It also boasts a 3.3% decarbonization rate and ships in sturdy, recyclable packaging.
Hot swappable fansAllows system to remain operational if a fan replacement is required.Washable filtersEasy to maintain, cleanable, deep loading mesh filter removes particles from the return air stream.AvailabilityPredictable coolingPlacing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.Dual A-B Power InputsDraws power from the UPS for power protection with dual feeds for redundancy.Rack inlet controlRack inlet control guarantees inlet temperature to IT equipment.Active response controlsMonitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.No minimum heat load requirementRefrigerant cooling system will operate from 0 - 100% of the design capacityTotal Cost of OwnershipVariable speed fansVariable speed fans reduce energy consumption during off-peak cooling periods.Row-based architectureCaptures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.AgilityModular designModular design provides scalable solutions to add cooling as demand increases.Scalable densitiesAllows for higher densities to be achieved by integrating containment with room, row and rack cooling system architectures.ServiceabilityEasy service accessAllows for all serviceable components to be replaced/maintained by easily accessible panels/doors.ManageabilityReal-Time Capacity MonitoringReal-time display of current and available cooling.Microprocessor controllerProvides proactive control and real-time monitoring via a four line, eighty character, alphanumeric display.Building management system integrationSend alarms and data points allowing you to manage critical building infrastructure from a single system.
APC ACF600 Netshelter Fan Tray 120 V 2U 135 CFM