APC AP7921B Netshelter Switched Rack PDU Switched 1U 16A 208/230V (8)C13 Switched IEC 60320 C20 200 V 208 V 230 V 8.20 ft Cord Length 1U Rack-mountable
APC AP7802B Netshelter Metered Rack PDU Metered 2U 30A 120V (16) 5-20 NEMA L5-30P 16 x NEMA 5-20R 100 V 120 V 12 ft Cord Length 2U Rack-mountable
APC AP8632 Netshelter Metered Metered-by-Outlet with Switching Rack PDU NEMA L5-30P 24 x NEMA 5-20R 100 V 120 V 2880 W 9.84 ft Cord Length 0U
APC AP8881 Netshelter Metered NetShelter Metered Rack PDU 0U 3PH 11kW 230V 16A or 11kW 230V 16A 36 C13 and 6 C19 outlets IEC 309 3P+N+PE cord
APC AP7541 Netshelter Basic PDU Basic Zero U 30A 200/208V 4.99kVA Zero U Rack-mountable
AvailabilityPower DelaysAllows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.Load indicator LEDIndicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.Integrates with StruxureWare Data Center ExpertAn IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the networkFlash UpgradeableQuickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)Remote Individual Outlet ControlRemotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).Network Management CapabilitiesFull-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.Local Current Monitoring DisplayThe aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only)Alarm ThresholdsDefine alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability)Marketing FeaturesPower DelaysAllows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.Alarm ThresholdsDefine alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.Remote Management CapabilitiesFull-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.Remote Individual Outlet ControlRemotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).Local Current Monitoring DisplayThe aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.AgilitySingle input power sourceSupply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.Wide range of input and output connectionsProduct family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.Rack-MountableIncludes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.
APC AP7552 Netshelter Basic Basic Rack PDU 20 x IEC 320-C13 4 x IEC 320-C19 3680VA Zero U Rack-mountable
APC AP6031A Netshelter Basic Basic 4-Outlet PDU NEMA L6-30P 4 x IEC 60320 C19 200 V 208 V 12 ft Cord Length 1U Rack-mountable Tower
APC APDU10452SW Netshelter Switched Metered Netshelter Rack Pdu Advanced Switched 3Ph 17.3Kw 208V 60A 460P9 42 Outlets
APC AP8858 Netshelter Metered Metered Rack 20-Outlets PDU IEC 60320 230 V 0U Rack-mountable