Tripp Lite 3 phase Monitored PDU / Power Distribution Unit offers real-time remote monitoring of voltage, frequency and load levels via built-in network connection. PowerAlert interface supports custom notification of user-specified remote conditions via email, secure web, SNMP, Telnet or SSH interface. PDU output current consumption in amps is displayed per-phase via front panel lighted digital display and can be monitored remotely to warn of potential overloads before critical IT mains breakers trip.- 8.6kW 3 phase 208V Monitored Power Distribution Unit / PDU with built-in web/network interface- Attached IEC-309 Blue 30A (3P+E) 208V 3 phase input plug with 3 ft. / 1m cord- 0U, 70 in. / 178cm vertical form factor supports installation in 2 or 4 post equipment racks- 36 total 208V outlets (30 C13, 6 C19) arranged in three breakered single phase output load banks- Lighted display with scroll-button reports power consumption in amps for all 3 loading banks, IP-address self-identification and 180 degree display rotation for overhead or raised floor power feeds- Built-in SNMP/ethernet interface reports voltage, frequency and PDU loading per-phase via network or secure web browser interface with options for user specified alarm and notification thresholds- Supports in-rack environmental reporting with optional ENVIROSENSE temperature / humidity sensor and rack access notification with up to 4 optional SRSWITCH door sensors- DHCP/Manual configuration support- 10/100 Mbps auto-sensing allows optimal communication with 10/100 Base-T networks- Real-time clock backup maintains the time of day and date even if the PDU is unpowered- Tiered access privileges allow an administrator and a guest to login via web browser for monitoring- Alert notifications via email or SNMP traps offer immediate event notification- Firmware upgrade ability supports future product enhancements- Supports HTTP, HTTPS, PowerAlert Network Management System, SMTP, SNMPv1, SNMPv2, Telnet, SSH, FTP, DHCP, BOOTP, NTP protocols- Fully compatible with FREE PowerAlert Network Management System / NMS Software- Included cord retention brackets keep vital network equipment plugged in and continuously powered- Toolless mounting supported in button-mount compatible racks, plus nut-and-bolt mounting brackets for other mounting applications
Tripp Lite SU8000RT3U1TF 8000VA / 8kVA / 7200 watt online, double-conversion UPS system offers complete power protection for critical network applications. This system delivers online, double-conversion UPS protection with zero transfer time, suitable for advanced networking applications. Fault-tolerant auto-bypass prevents unexpected service interruptions during UPS overload or internal fault conditions. Included detachable PDU with manual bypass switch enables hot-swappable replacement of entire UPS power module with no interruption to connected equipment. Enhanced availability, fault tolerance and simple hot-swap replacement options make this UPS ideal for advanced networking applications in data centers, computer rooms, network closets and rugged industrial locations.- Tripp Lite SU8000RT3U1TF 8kVA / 8000VA / 7200 watt on-line, double-conversion UPS system in 8U total rack/tower configuration (3U UPS power module, 3U external battery pack and 2U step-down transformer)- Detachable PDU with manual bypass switch enables hot-swappable UPS power module replacement with no interruption in output power to connected networking equipment- Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions- Hardwire input; 2 L6-30R, 4 L6-20R and 12 5-15/20R outlets- Maximum installed rack depth of only 32.5 in. / 82.6cm inches- Full-time active power conditioning provides clean, continuous dual-conversion AC output free of voltage fluctuations, power interruptions and line noise- Double-conversion operation converts raw input from AC to DC, then re-synthesizes output power back to perfect sine wave AC with enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types- Maintains full-time sine wave output within 2% of 208/120V nominal at 60Hz during brownouts as low as 100V and overvoltages as high as 300V- Expandable runtime is supported with optional BP240V10RT3U; BP240V557C-1PH; BP240V787C-1PH; BP240V1037C-1PH; BP240V1407C-1PH external battery packs- Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual)- Highly efficient operation in optional economy mode significantly reduces BTU heat output and operating energy costs- Battery independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and require replacement- PowerAlert monitoring software offers detailed site power and UPS updates with support for safe auto-shutdown of connected systems as UPS batteries become depleted- Includes Free PowerAlert monitoring software packages; PowerAlert LOCAL for desktops and small business networks, PowerAlert NSA (Network Shutdown Agent) for larger networks and PowerAlert NMS (Network Management System) for monitoring up to 250 SNMP-enabled UPS, PDU and other networking devices- Supports detailed monitoring of equipment load levels, self-test data and utility power conditions via built-in RS-232 and USB interfaces- HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X- Optional SNMPWEBCARD offers communications and control via secure remote web and network interfaces- Optional RELAYIOCARD supports six configurable hard contact closure outputs for custom event notification- Optional RELAYIOMINI interface module offers three configurable hard contact closure outputs for custom event notification (requires removal of USB interface module)- Supports Emergency Power Off (EPO) via built-in interface- Included rail kit supports 8U 19 inch rackmount installation in 4 post racks- Optional 2POSTRMKITHD supports installation in 2 post 19 inch racks- Optional 2-9USTAND supports upright tower placement- Front panel LEDs and LCD readout with scroll controls and password option supports visual monitoring of all major UPS functions and advanced UPS settings for charge level, nominal voltage selection, frequency conversion and other operational parameters- LED / LCD display panel rotates for viewing in rackmount or tower configurations- Network-grade AC surge and noise suppression- Industrial mode option (factory preset) enables supports high current startup loads by momentarily switching to bypass mode in response to short duration overload conditions- External battery packs are field replaceable and hot swappable
9PXM ENCL 12-SLOT ENCL 4 8 12 16 OR 20 KVA - TAA Compliance 9PXM12BBGHJ Eaton Corporation 9PXM12BBGHJ Eaton Corporation
Powerware Warranty/Support - Extended Warranty - 3 Year - Warranty - x Next Business Day - Exchange - Parts - Physical - TAA Compliance
The Eaton 9155 8kVA UPS with 32 battery modules provides extended runtime and continuous power protection for critical systems. Its 2-high battery configuration ensures reliable backup during power outages, making it an ideal solution for data centers and IT environments that demand high efficiency and uninterrupted power.
The UPS Smart 700VA 450W Tower AVR is a hospital-grade UPS designed for medical applications. With pure sine wave output, USB, DB9 ports, and TAA compliance, this UPS provides reliable power protection for medical equipment and systems.
Eaton Powerware 18 kW External Power Array Cabinet - 2 x Expansion Slots - Serial - Ethernet
Eaton 124100027-002 Maintenance Bypass Panel - 15 kVA
Eaton Power Array Cabinet
Note: Search results and information may differ as they are provided by a third party.
In Stock*: Product stock is updated from the last business day and can change.
MFR: Netgear, Inc
Qty: 1
Part #: GS105NA