The solid Partition allows overhead routing of networking cables on top of the NetShelter enclosures and 4-post racks Two partitions attach without tools to the roof in a variety of depths The solid partition is designed to be mounted in the front for a clean look Each partition ships with ground studs and one 8 inch/203mm grounding strap
Cable Ladder Corner Clamp Kit - 115lb
Direct drive motorsStress on bearings is nearly eliminated, increasing useful life. Allows integral fan/motor assembly to be factory balanced, which lowers vibration and expedites startup.ServiceabilityEasy service accessAllows for all serviceable components to be replaced/maintained by easily accessible panels/doors.AgilityScaleable densitiesAllows for higher densities to be achieved by integrating containment with room, row and rack cooling system architectures.Modular designModular design provides scalable solutions to add cooling as demand increases.Total Cost of OwnershipVariable speed fansVariable speed fans reduce energy consumption during off-peak cooling periods.In-Row architectureCaptures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.AvailabilityRack inlet temperature controlReduces the risk of hot spots at the rack levelActive response controlsMonitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.Predictable coolingPlacing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.ManageabilityBuilding management system integrationSend alarms and data points allowing you to manage critical building infrastructure from a single system.Real-Time capacity monitoringReal-time display of current and available cooling.Microprocessor controllerUtilizes intelligent, active response control, and real-time monitoring. The system is controlled by a microprocessor providing high level control functionality and human interface via a four line, eighty character, alphanumeric display
EcoLEDgy Driven LightingIntegrated high efficiency LED lighting with on/off motion sensorsEfficiencyIncreases the capacity of the air conditioner by supplying a warmer return air temperature.Active Airflow ControlMonitors and actively adjust cooling unit airflow in containment systems, while providing visibility to effective cooling to critical IT equipment.
Uniflair Plenum Chamber - Frame Size 7 - Gray
Rack components that can be added to existing racks if requirements change.Includes:Door handle, Door mounting hardware, Installation guide, Key(s)
VERTICAL FIBER ORGANIZERBLACK
APC ACSC100 UPS 3-Series Accessories Uniflair InRow SC, 300mm, Air Cooled, Self-contained 200-240V 60Hz
Introducing the redesigned APC NetShelter SX rack enclosure - trusted, versatile, and built for demanding IT environments. With larger load capacities and more space for equipment, it enables higher-density computing. Choose from standard, wide, extra wide, and large-depth options. The modern look is perfect for colocation and customer-facing businesses. Simplify workflows with easy access to cabling and equipment, and optimize airflow and cable management with our wide range of APC accessories. The 270° (180° bayed) opening doors keep aisles clear, while 80% door perforation improves airflow for high-powered servers. Built sustainably with all-steel construction, it lasts for years and can be used for various applications. It also boasts a 3.3% decarbonization rate and ships in sturdy, recyclable packaging.
Active response controlsMonitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.Total Cost of OwnershipEconomizationAchieved by utilizing cool ambient air during winter months to take advantage of economizer hours and eliminating compressor operation.Indirect Heat ExchangeA polymer heat exchanger allows the data center and outside airstreams to remain separated, thereby preventing contamination and humidity influences to the data center airstream.Zero White SpaceAll cooling equipment is placed outside the data center, allowing for valuable white space to be fully utilized for IT equipment.Variable speed fansVariable speed fans reduce energy consumption during off-peak cooling periods.Supplemental Mechanical CoolingProvides extra capacity to augment economization, extending annual hours of energy savings.AvailabilityActive response controlsMonitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.Redundant ComponentsSingle points of failure in the system have redundant compononents to maintain availability and reliability.EconomyGreen RefrigerantEnvironmentally friendly refrigerant that can offer LEED points.Pulse Powered Water Treatment SystemEliminates the use of chemicals in the system, allowing the water to be re-used or drained without harming the environment.AgilityPre-engineered systemAllows for fast design and installationScalable DesignModular design provides scalable solutions to add cooling as demand increases.ServiceabilityOperational ServiceAllows critical components to be maintained/replaced while the system is in operation.Easy service accessAllows for all serviceable components to be replaced/maintained by easily accessible panels/doors.
Note: Search results and information may differ as they are provided by a third party.
In Stock*: Product stock is updated from the last business day and can change.
MFR: Netgear, Inc
Qty: 1
Part #: GS105NA
