APC AP8866 Netshelter Metered Rack PDU 2G metered 0U 17.2kW 6 ft Cord Length 0U Rack-mountable
APC SBP1500RM Maintenance Bypass Panels Maintenance Bypass Panels Input: 120V Input Connections: NEMA 5-15P Cord Length: 8 feet ( 2.44 meters )
APC NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 8.6kW, 208V 30A, L21-30P, 42 Outlet.
APC AP7821B Netshelter Metered power distribution unit (PDU) 8 AC outlet(s) 0U/1U Black
APC AP9559 Netshelter Basic Basic Rack 3.68kVA PDU 10 x IEC 320-C13 2 x IEC 320-C19 3.68kVA 1U 19" Rack-mountable
APC AP8832 Netshelter Metered Metered Rack PDU NEMA L5-30P 24 x NEMA 5-20R 100 V 120 V 2880 W 9.84 ft Cord Length 0U Rack-mountable
APC AP7920B Netshelter Switched Rack PDU Switched 1U 12A/208V 10A/230V (8)C13 Switched IEC 60320 C14 200 V 208 V 230 V 6.50 ft Cord Length 1U Rack-mountable
APC AP8870 Netshelter Metered Rack Mount PDU Metered 208V/30A (28) Outlets 0U Vertical Rackmount
APC AP7532 Netshelter Basic Basic Rack PDU 24 x NEMA 5-20R 2880VA Zero U Rack-mountable
APC NetShelter Rack PDU Advanced (11K Series) provides reliable power distribution to IT equipment within server and/or networking racks. Switched outlets allow for turning outlets on or off remotely. Outlet and PDU level power metering provide power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparalleled deployment flexibility. Maximum outlet density with 40 outlets in a 2.2 in. (5.6 cm) wide form factor allows for more equipment in the rack. Outlets on the PDUs are color coded and labeled by breaker. Live Swap the NMC3 to minimize downtime in the unlikely event of an NMC power event. The rack PDU integrates with EcoStruxure IT through an NMC3 and can be accessed and configured via web, SNMP, and command line interface (CLI). A 10-foot (3-meter) input cord makes it easier for the PDU to reach the power supply. Rated to operate up to 60 C (140 F) at full load ensures reliability and availability even in today's high-density deployments. One gigabit Ethernet/network port (10/100/1000) enhances and standardizes network connectivity. Two link ports are available to cascade to up to 32 PDUs, with a network port sharing (NPS) feature to enable power sharing between Rack PDUs in the cascading group. Track or bill power usage confidently with 1% metering accuracy. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. For data center deployments across multiple regions,